Baldor VS1MD Computer Drive User Manual


 
7-2 VS1MD AC Drive User Manual
7.2 Display Group Parameters
Parameters in this group are display only and can be used to monitor drive
conditions. To change the active display for the drive, use parameter H72 - Power
On Display.
d0 Frequency Command
Range: 0.0 to Frequency High Limit (P36) [Hz]
Default: Read Only
Displays the value of the active frequency command. The commanded
frequency is displayed even if the drive is not running.
d1 Motor RPM
Range: 0.0 Motor RPM (based on P33 Motor
Poles) [RPM]
Default: Read Only
Displays the output motor RPM. Motor RPM is scaled based on output
frequency present on terminals U, V and W based on the setting in P33
– Motor Poles.
d2 Output Current
Range: 0.0 to Motor Rated Current (P32) [Amps]
Default: Read Only
Displays the value of the output current present at terminals U, V and W.
d3 Output Voltage
Range: 0.0 to Drive Rated Voltage [volts]
Default: Read Only
Displays output voltage present at U, V, W.
d4 Output Power
Range: 0.0 to (Drive Rated Power x 2) [kW]
Default: Read Only
Displays the value of the output power present at terminals U, V and W.