Baldor VS1MD Computer Drive User Manual


 
7-26 VS1MD AC Drive User Manual
t63 Frequency Loss Wait Time
Range: 0.1-120 [sec]
Default: 1.0
Access Tunable
See Also: P40, t35, t62
This is the time delay before the drive takes action in the event of a
command frequency loss. If there is no frequency command input during
the time set in this parameter, the drive starts to operate in the mode
selected in t62.
t64 Communication Time Setting
Range: 2-100 [ms]
Default: 5
Access Tunable
See Also: t59-t61, t65-t81
Frame Communication time.
t65 Parity/Stop Bit Setting
Range: 0=Parity: None, Stop Bit: 1
1=Parity: None, Stop Bit: 2
2=Parity: Even, Stop Bit: 1
3=Parity: Odd, Stop Bit: 1
Default: 0
Access Tunable
See Also: t59-t61, t64, t66-t81
When the protocol is set, the communication format can be set.
t66 Read address register 1
t67 Read address register 2
t68 Read address register 3
t69 Read address register 4
t70 Read address register 5
t71 Read address register 6
t72 Read address register 7
t73 Read address register 8
Range: 0-42239
Default: t66=5, t67=6, t68=7, t69=8, t70=9, t71=10, t72=11, t73=12
Access Tunable
The user can register up to 8 discontinuous addresses and read them all
with one read command.