Baldor VS1MD Computer Drive User Manual


 
7-16 VS1MD AC Drive User Manual
23 = Analog Hold: Locks the analog speed reference at the last value
when the input was closed. Available when P40 = Frequency setting
method is set in the range of 2 ~ 7.
24 = Accel/Decel Disable: Disables the acceleration or deceleration ramp
while the digital input is closed, holding the reference at its last value.
25 = Up/Down Frequency Save Initialization: When the digital input is
active, the last Up/Down frequency is saved. Useable when digital inputs
are configured as 15 = Frequency Increase (UP) and 16 = Frequency
Decrease (DOWN).
t9 Filtering Time Constant for Multi-function input terminal
Range: 1 - 15
Default: 4
Access Tunable
See Also: t1-t8
The higher the value is set, the slower the responsiveness of the digital
input becomes.