Baldor VS1MD Computer Drive User Manual


 
Parameter Descriptions 7-21
t35 Criteria for Analog Input Signal Loss
Range: 0 = Disabled
1 = Activated below half of set value
2 = Activated below set value
Default: 0
Access Tunable
See Also: t32-t33, t36, t41, t46, t62-t63
Selects the drive mode when frequency reference set by the Analog (V1, I)
input terminal or communication option is lost.
Example 1) The inverter determines the freq reference is lost when P40 –
Freq set method is set to 3 (Analog V1 input), t16 to 1 and analog input
signal is less than half the value set in t36.
Example 2)The inverter determines the freq reference is lost when P40 –
Freq set method is set to 6 (V1+I), t16 to 2 and V1 input signal is either
below the value set in t36 or I input value is less than the t46 value.
Example diagram when t35 is set to 2, I62 to 2, I63 to 5.0 sec and t32 to 11:
t36 Analog Input 0 to -10V (NV) Min voltage
Range: 0 to -10V
Default: 0
Access Tunable
See Also: P40, t37
Sets the minimum voltage of the NV (-10 to 0V) input.
0
Disabled (Does not check the
analog input signal loss)
1
When half the value set in t36,
t41, t46 is entered
t35
[Criteria for analog input
signal loss]
2
When less than the value set in
t36, t41, t46 is entered