Datalogic Scanning 4410 Scanner User Manual


 
Bar Code Parameters
Product Reference Guide F-11
European Article Numbering-8
(EAN-8)
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the EAN-8 sym-
bology.
0
5
1
8
On or
Off
Off On On
99
Enable
Aggres-
sive
Decoding
Enables more aggressive decoding
algorithms to be used in order to
scan hard to read labels.
0
5
1
9
On or
Off
Off On Off
9
Send
Check
Digit
Instructs the terminal to include the
check digit in the label transmis-
sion.
0
5
1
A
On or
Off
Off On Off
99
Convert
EAN-8 to
EAN-13
Instructs the decoder to expand
EAN-8 labels to their EAN-13
equivalents. Any EAN-13 parame-
ters will then apply to the result.
0
5
1
B
On or
Off
Off On Off
9
Read Veri-
fication
Sets the number of times a label
must be read before it is transmit-
ted.
0
5
2
6
01 - 04 01 02 01
9
User ID
Specifies the symbology identifier
(if any) that is sent by the decoder
when parameter Send Code ID
(Index 0025) is set to 3.
ASCII
code zero (null) is used to indicate
that an identifier is not to be sent for
the symbology.
0
5
2
7
Any
single
ASCII
charac-
ter
(00 =
Off)
'G' 'G' 'G'
99
Code Parameter/ Description
I.
D.
#
Accep-
table
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er