Datalogic Scanning 4410 Scanner User Manual


 
Programming Parameters
F-26
Falcon
®
4400 Series with Windows
®
CE
Datama-
trix User
Code ID
Specifies the symbology identifier
(if any) that is sent when parame-
ter Send Code ID (Index 0025) is
set to 3.
ASCII code zero (null) is
used to indicate that an identifier is
not to be sent for the symbology.
0
B
2
3
Any sin-
gle
ASCII
charac-
ter (00 =
Off)
‘V’ ‘V’ ‘V’
9
Composite
Enter 1 for On
and 0 for Off.
Compos-
ite Enable
Enables/disables the Composite
symbology.
0
A
1
0
On or
Off
Off On Off
9
Compos-
ite to
UCC/EAN-
128
Instructs the decoder to transmit
the label data as one or more
UCC-128 labels. The transmis-
sion will use the UCC-128 AIM
identifier.
0
A
1
4
On or
Off
Off Off Off
9
Compos-
ite
Minimum
Set the minimum bar code label
length to be less than or equal to
maximum label length.
0
A
2
8
1 - 2435 1 2435 1
9
Compos-
ite Maxi-
mum
This feature specifies the maxi-
mum allowable length of a label.
The length includes check and
data characters, if applicable.
Maximum Label Length should be
greater than or equal to Minimum
Label Length.
0
A
2
9
1 - 2435 1 2435 2435
9
Code Parameter/ Description
I.
D.
#
Accept
able
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er