Datalogic Scanning 4410 Scanner User Manual


 
Programming Parameters
F-16
Falcon
®
4400 Series with Windows
®
CE
Read Veri-
fication
Sets the number of times a label
must be read before it is transmit-
ted.
0
6
2
6
01 - 04 01 02 01
9
User ID
Specifies the symbology identifier
(if any) that is sent by the decoder
when parameter Send Code ID
(Index 0025) is set to 3.
ASCII
code zero (null) is used to indicate
that an identifier is not to be sent for
the symbology.
0
6
2
7
Any
single
ASCII
charac-
ter
(00 =
Off)
'H' 'H' 'H'
99
Pharmacode 39 (Code 32)
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the Pharmacode
39 (Code 32) symbology.
0
1
1
0
On or
Off
Off On Off
99
Send
Checksum
Instructs the terminal to include the
checksum in the label transmission.
0
1
1
2
On or
Off
Off Off Off
9
Send Start/
Stop
Instructs terminals to prefix a Phar-
macode 39 label with an “A” prior to
transmission.
0
1
1
3
On or
Off
Off On Off
9
User ID
Specifies the symbology identifier
(if any) that is sent when parameter
Send Code ID (Index 0025) is set to
3.
ASCII code zero (null) is used
to indicate that an identifier is not to
be sent for the symbology.
0
1
2
7
Any
single
ASCII
charac-
ter
(00 =
Off)
'Y' 'Y' 'Y'
99
Code Parameter/ Description
I.
D.
#
Accep-
table
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er