Programming Parameters
F-20
Falcon
®
4400 Series with Windows
®
CE
Maximum
Label
Length
This feature specifies the maximum
allowable length of a Standard 2 of
5 label. The length includes check
and data characters. Maximum
Label Length should be greater
than or equal to Minimum Label
Length.
0
2
2
1
01 - 50 01 50 10
99
Read Veri-
fication
Sets the number of times a label
must be read before it is transmit-
ted.
0
2
2
2
01 - 04 01 02 01
9
User ID
Specifies the symbology identifier
(if any) that is sent when parameter
Send Code ID (Index 0025) is set to
3.
ASCII code zero (null) is used
to indicate that an identifier is not to
be sent for the symbology.
0
2
2
3
Any
single
ASCII
charac-
ter
(00 =
Off)
'F' 'F' 'F'
99
Trioptic
Enter 1 for On
and 0 for Off.
Enable
Enables/disables the Trioptic sym-
bology.
0
1
0
8
On or
Off
Off On Off
99
Enable
Aggres-
sive
Decoding
Enables more aggressive decoding
algorithms to be used in order to
scan hard to read labels.
0
1
0
9
On or
Off
Off On Off
9
Read Veri-
fication
Sets the number of times a label
must be read before it is transmit-
ted.
0
1
2
4
01 - 04 01 02 01
9
Code Parameter/ Description
I.
D.
#
Accep-
table
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er