Datalogic Scanning 4410 Scanner User Manual


 
Programming Parameters
F-14
Falcon
®
4400 Series with Windows
®
CE
Send
Checksum
Instructs the terminal to include the
checksum in the label transmission.
0
2
0
B
On or
Off
Off Off Off
9
Minimum
Label
Length
Set the minimum label length to be
less than or equal to maximum
label length.
0
2
2
4
01 - 50 01 01 06
99
Maximum
Label
Length
This feature specifies the maximum
allowable length of a Matrix 2 of 5
label. The length includes check
and data characters. Maximum
Label Length should be greater
than or equal to Minimum Label
Length.
0
2
2
5
01 - 50 01 50 10
99
Read Veri-
fication
Sets the number of times a label
must be read before it is transmit-
ted.
0
2
2
6
01 - 04 01 02 01
9
User ID
Specifies the symbology identifier
(if any) that is sent by the decoder
when parameter Send Code ID
(Index 0025) is set to 3.
ASCII
code zero (null) is used to indicate
that an identifier is not to be sent for
the symbology.
0
2
2
7
Any
single
ASCII
charac-
ter
(00 =
Off)
'D' 'D' 'D'
99
Code Parameter/ Description
I.
D.
#
Accep-
table
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er