Datalogic Scanning 4410 Scanner User Manual


 
Bar Code Parameters
Product Reference Guide F-33
Imaging
Rotation
Specifies how much the imager will rotate
images it takes.
0
C
2
5
0 to 3 (0
to 270
degrees
in 90
degree
incre-
ments)
00 0
Imaging
Scale
Specifies how much the imager is to scale
images it takes. It is the percentage of the
original image that is used to create the
final image. Scales the x,y dimensions of
the image.
0
C
2
6
0 =
100%
1 = 50%
(1/4
size)
2 = 33%
(1/9
size)
3 = 25%
(1/16
size)
00 0
Imaging For-
mat
Specifies the storage format an imager will
use when taking images.
0 (TIFF monochrome)
1 (TIFF 8 bit grayscale)
2 (JPEG 8 bit grayscale)
3 (BMP monochrome)
4 (BMP 8 bit grayscale)
0
C
2
7
0 to 4 2 2 2
Imaging
Brightness
Specifies the brightness level an imager will
use when taking images
0
C
2
8
0 to 99
(low to
high)
50 50 50
Imaging
Edge Sharp-
ness
Specifies how much (if at all) an imager will
attempt to sharpen edges in images it
takes.
0
C
2
9
0 (off), 1
to 99
(dull to
sharp)
00 0
Code Parameter/ Description
I.
D.
#
Accep-
table
Input
Defaults
Min Max Factory