Dell 3548 Switch User Manual


 
Configuring System Information 169
Figure 6-54. Optical Transceiver Diagnostics Table
In addition to the fields in the Optical Transceiver Diagnostics page, the Optical Transceiver Diagnostics
Ta bl e contains the following field:
Unit No
. — The unit number for which the cable is displayed.
N/A
— Not Available, N/S - Not Supported, W - Warning, E - Error
Performing Fiber Optic Cable Tests Using CLI Commands
The following table contains the CLI command for performing fiber optic cable tests.
The following is an example of the CLI command:
Table 6-32. Fiber Optic Cable Test CLI Commands
CLI Command Description
show fiber-ports optical-
transceiver
[
interface
]
[
detailed
]
Displays the optical transceiver
diagnostics.
Console# show fiber-ports optical-transceiver detailed
Port Temp
[C]
Voltage Current
[Volt]
Output
[mA]
Input
[mWatt]
POWER
TX
[mWatt]
LOS
Fault
---- ---- ------ ----- ------ ------ ------ -----
1/g1 48 5.15 50 1.789 1.789 No No
1/g2 43 5.15 10 1.789 1.789 No No