Chapter 7 Servo Parameters|ASDA-B Series
7-4 Revision February 2008, Doc. Name: 2006PDD23000009
Basic Parameters
Control
Mode
Parameter Name Function Default Unit
P S T
P1-44▲
GR1
Electronic Gear Ratio (1st Numerator)
(N1)
1 pulse
{
P1-45▲
GR2 Electronic Gear Ratio (Denominator) 1 pulse
{
P1-46▲
GR3 Encoder Output Pulse Number 2500 pulse
{ { {
P1-47
~ P1-51
Reserved
P1-52 RES1 Regenerative Resistor Value 40 Ohm
{ { {
P1-53 RES2 Regenerative Resistor Capacity 60 Watt
{ { {
P1-54 PER Positioning Completed Width 100 pulse
{
P1-55 MSPD Maximum Speed Limit rated speed rpm
{ { {
Explanation of symbols (marked after parameter)
(★) Read-only register.
(▲) Parameter cannot be set when Servo On (when the servo drive is enabled).
(●) Parameter is effective only after the servo drive is restarted (after switching power off and on).
(■) Parameter setting values are not retained when power is off.