Delta Electronics ASDA-B Network Card User Manual


 
Chapter 10 Troubleshooting|ASDA-B Series
Revision February 2008, Doc. Name: 2006PDD23000009 10-11
ALE 43 : Error communication response address
Potential Cause Checking Method Corrective Actions
Receive the error
communication
response address
Check if the sending and receiving
communication address are the same.
Check if the communication setting
is correct by using P8-05.
Verify the sending and receiving
data format.
ALE 44 : Error communication response command
Potential Cause Checking Method Corrective Actions
Respond the error
communication
command.
Respond the error Modbus command
Verify the sending and receiving
data format.
ALE 45 : Communication parameter address error
Potential Cause Checking Method Corrective Actions
Respond the error
parameter address
Check if the sending and receiving
communication code are the same.
Verify the sending and receiving
data format.
ALE 46 : Communication parameter content error
Potential Cause Checking Method Corrective Actions
Respond error
parameter content
when reading
parameter.
The data length of the content is error.
Verify the sending and receiving
data format.
Respond error
parameter content
when writing
parameter.
The data content is in error.
Verify the sending and receiving
data format.
ALE 47 : Drive specification error
Potential Cause Checking Method Corrective Actions
Parameter SAVE
operation is in error.
Use P8-13 to check if the specification stored in
the memory block match the actual servo drive
specification when executing SAVE function
(Save parameter settings to the Keypad).
1. Select the unused memory
block to save the parameter.
2. Delete the memory block.
Parameter WRITE
operation is in error.
Use P8-13 to check if the specification stored in
the memory block match the actual servo drive
specification when executing WRITE function
(Parameter settings written out to the Drive).
Select the correct memory block.
ALE 48 : Fast editing function error
Potential Cause Checking Method Corrective Actions
The function of static
and auto-tuning is in
error.
The setting of P2-32 is incorrect. Set P2-32 to Manual mode.
The function of dynamic
auto-tuning is in error.
Execution time out or the function is not
executed completely.
Please contact your distributor for
assistance or contact with Delta.