Delta Electronics ASDA-B Network Card User Manual


 
Chapter 7 Servo Parameters|ASDA-B Series
Revision February 2008, Doc. Name: 2006PDD23000009 7-25
P1 - 01
CTL Control Mode and Output Direction Communication Addr.: 0101H
Default: 0 Related Section:
Applicable Control Mode: P/S/T P mode: See Section 6.2.1
Unit: pulse (P mode), rpm (S mode), N.M (T mode) S, Sz mode: See Section 6.3.1
Range: 0 ~ 110 T, Tz mode: See Section 6.4.1
Settings:
ASD-PU-01A ASD-PU-01B
Control Mode Settings:
P S T Sz Tz
00
02
03
04
05
06
07
10
Torque Output Direction Settings:
0 1
Forward
Reverse
P: Position control mode (command from external signal)
S: Speed control mode (external command / internal command)
T: Torque control mode (external command / internal command)
Sz: Zero speed control mode (internal speed command)
Tz: Zero torque control mode (internal torque command)
P1 - 02
PSTL Speed and Torque Limit Communication Addr.: 0102H
Default: 0 Related Section:
Applicable Control Mode: P/S/T Section 6.1.1, Section 6.6.2
Unit: N/A Table 7.A
Range: 0 ~ 11