Delta Electronics ASDA-B Network Card User Manual


 
Chapter 7 Servo Parameters|ASDA-B Series
7-68 Revision February 2008, Doc. Name: 2006PDD23000009
Group 8: P8-xx Keypad Parameters
NOTE
All the keypad parameters cannot be download to PC or the servo drive via communication. Users only can
edit and change the keypad parameters through the keypad.
P8 - 00
KVER Keypad Firmware Version Communication Addr.: 0800H
Default: Factory setting Related Section: N/A
Applicable Control Mode: P/S/T
Unit: N/A
Range: N/A
P8 - 01 KFUN Keypad Communication and Reset Setting Communication Addr.: 0801H
Default: 1 Related Section: N/A
Applicable Control Mode: P/S/T
Unit: N/A
Range: 0 ~ 011
Settings:
ASD-PU-01A
ASD-PU-01B
Communication Method Settings:
0: If 0 is set, it indicates the keypad is the slave side during communication. 0 must be set
when communicating with PC, or there will be a communication fault.