Delta Electronics ASDA-B Network Card User Manual


 
Chapter 7 Servo Parameters|ASDA-B Series
7-8 Revision February 2008, Doc. Name: 2006PDD23000009
Group 4: P4-xx
Diagnosis Parameters
Control
Mode
Parameter Name Function Default Unit
P S T
P4-00
ASH1 Fault Record (N) 0 N/A
{ { {
P4-01
ASH2 Fault Record (N-1) 0 N/A
{ { {
P4-02
ASH3 Fault Record (N-2) 0 N/A
{ { {
P4-03
ASH4 Fault Record (N-3) 0 N/A
{ { {
P4-04
ASH5 Fault Record (N-4) 0 N/A
{ { {
P4-05 JOG JOG Operation 20 rpm
{ { {
P4-06▲■
FOT Force Output Control 0 N/A
{ { {
P4-07
ITST Input Status or Force Input Control N/A N/A
{ { {
P4-08 Reserved
P4-09
MOT Output Status Display
N/A
N/A
{ { {
P4-10
CEN Adjustment Function 0 N/A
{ { {
P4-11 SOF1 Analog Speed Input Drift Adjustment 1
Factory
setting
N/A
{ { {
P4-12 SOF2 Analog Speed Input Drift Adjustment 2
Factory
setting
N/A
{ { {
P4-13 TOF1 Analog Torque Drift Adjustment 1
Factory
setting
N/A
{ { {
P4-14 Reserved
P4-15 COF1
Current Detector Drift Adjustment (V1
phase)
Factory
setting
N/A
{ { {
P4-16 COF2
Current Detector Drift Adjustment (V2
phase)
Factory
setting
N/A
{ { {
P4-17 COF3
Current Detector Drift Adjustment (W1
phase)
Factory
setting
N/A
{ { {
P4-18 COF4
Current Detector Drift Adjustment (W2
phase)
Factory
setting
N/A
{ { {
P4-19 TIGB IGBT NTC Calibration
Factory
setting
N/A
{ { {
P4-20 Reserved
P4-21 Reserved
P4-22 SAO Analog Speed Input Offset 0 mV
{
P4-23 TAO Analog Torque Input Offset 0 mV
{
Explanation of symbols (marked after parameter)
() Read-only register.
() Parameter cannot be set when Servo On (when the servo drive is enabled).
() Parameter is effective only after the servo drive is restarted (after switching power off and on).
() Parameter setting values are not retained when power is off.