¾ It is not recommended to frequently power the drive on and off. Do not turn the drive off and on more than once
per minute as high charging currents within the internal capacitors may cause damage.
Main Circuit Terminal Wiring
¾ Insert only one wire into one terminal on the terminal block.
¾ When inserting wires, please ensure that the conductors are not shorted to adjacent terminals or wires.
¾ Please use Y-type terminals to tighten the ends of wires.
¾ Ensure to double check the wiring before applying power to the drive.
NOTE
1) In this manual, actual measured values are in metric units. Dimensions in (imperial
units) are for reference only. Please use metric for precise measurements.