System Management: Vendor Commands
10009109-01 ATCA-9305 User’s Manual
7-25
Get Status
The IPMC firmware notifies the payload about changes of all status bits except for bits 0-2
by sending an unprintable character (ASCII 07, BELL) over the Payload Interface. The pay-
load is expected to use the Get Status command to identify pending events and other SIPL
commands to provide a response (if necessary). The event notification character is sent in a
synchronous manner, and does not appear in the contents of SIPL messages sent to the pay-
load.
Table 7-17: Get Status Command
Set Local FRU LED State OEM 2E, 2F 18
Get Local FRU LED State OEM 2E, 2F 19
Update Discrete Sensor OEM 2E, 2F 1A
Update Threshold Sensor OEM 2E, 2F 1B
Reserved for Message Listeners OEM 30, 31 10
Add Message Listener OEM 30, 31 11
Remove Message Listener OEM 30, 31 12
Get Message Listener List OEM 30, 31 13
Update Firmware Progress Sensor OEM 30, 31 F0
Type: Byte: Data Field:
Request Data 1:3 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data 1 Completion Code
2:4 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Command: (continued) netFn: LUN: Cmd: