Emerson ATCA-9305 Computer Hardware User Manual


 
System Management: Vendor Commands
ATCA-9305 User’s Manual 10009109-01
7-38
Set Local FRU LED State
The Set Local FRU LED State command is used to change the local state of a FRU LED.
Table 7-38: Set Local FRU LED State Command
Type: Byte: Data Field:
Request Data 1:3 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
4 FRU Device ID
5LED ID
00h Blue LED (Hot Swap)
01h LED 1 (OOS)
02h LED 2
03h LED 3
04h-FEh OEM defined LEDs
FFh Lamp Test (all LEDs under management control are
addressed)
6 LED Function
00h LED off override
01h-FAh LED blinking override
FBh Lamp Test state Turn on LED specified in byte 3 for the
duration specified in byte 5, then return to the highest
priority state.
FCh LED state restored to Local Control state
FDh-FEh reserved
FFh LED on override
7On Duration
LED on-time is measured in tens of milliseconds
Lamp Test time in hundreds of milliseconds if byte 4=FBh, time
value must be less than 128. Other values when Byte 4=FBh are
reserved. Otherwise, this field is ignored and shall be set to 0h.
8 Color parameter specifies the color of the LED in the local state for
multi-color LEDs
9 If the off-first flag parameter is 0, the on part of the blink cycle of
the LED precedes the off part of the cycle. Otherwise, the off part
of the blink cycle precedes the on part of the cycle.
Response Data 1 Completion Code
2:4 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)