Emerson ATCA-9305 Computer Hardware User Manual


 
System Management: Vendor Commands
10009109-01 ATCA-9305 User’s Manual
7-37
To avoid deadlocks that may occur if the payload software does not respond, the IPMC pro-
vides a special time-out for the payload shutdown sequence. If the payload does not send
the Graceful Reset command within a definite period of time, the IPMC assumes that the
payload shutdown sequence is finished, and sends a Module Quiesced Hot Swap event to
the ATCA-9305 controller.
Table 7-36: Get Payload Shutdown Time-Out Command
Set Payload Shutdown Time-Out
The Set Payload Shutdown Time-Out command is defined as follows:
Table 7-37: Set Payload Shutdown Time-Out Command
Type: Byte: Data Field:
Request Data 1:3 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data 1 Completion Code
2:4 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
5:6 Time-Out measured in hundreds of milliseconds, LSB first
Type: Byte: Data Field:
Request Data 1:3 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
4:5 Time-Out measured in hundreds of milliseconds, LSB first
Response Data 1 Completion Code
2:4 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)