Management Processor Monitor: Command-Line Features
ATCA-9305 User’s Manual 10009109-01
9-2
Figure 9-1: Example MPC8548 Monitor Start-up Display
This prompt is also displayed as an indication that the monitor has finished executing a
command or function invoked at the command prompt (except when the command loads
and jumps to a user application). The hardware product name (ATCA-9305), and current
software version number are displayed in the prompt.
Prior to the console port being available, the monitor will display a four-bit hexadecimal
value on LED1 through LED4 to indicate the power-up status (see
Ta bl e 9- 1). See Fig.2-4 for
the debug LED locations. In the event of a specific initialization error, the LED pattern will be
displayed and the board initialization will halt.
Table 9-1: Debug LED Codes
LED Code: Power-up Status: LED Value:
BOARD_PRE_INIT start booting, setup BATs done 0x01
SERIAL_INIT console init done 0x02
Hardware initialization
Monitor command prompt
U-Boot 1.1.4 (Jan 8 2007 - 16:07:48)1.0
CPU: 8548_E, Version: 2.0, (0x80390020)
Core: E500, Version: 2.0, (0x80210020)
Clock Configuration:
CPU: 999 MHz, CCB: 399 MHz,
DDR: 199 MHz, LBC: 49 MHz
Board: ATCA-9305 ATCA Blade
Emerson Network Power, Embedded Computing Inc.
cPLD Ver: 2
I2C: ready
Clearing ALL of memory
................
DRAM: 512 MB
Testing Top 1M Area of DRAM........PASSED
Relocating code to RAM
FLASH: [4MB@e0000000][4MB@e1000000]8 MB
L2 cache: enabled
In: serial
Out: serial
Err: serial
Ser#: 1096
Diags Mem: PASSED
Diags I2C: PASSED
Diags Flash: PASSED
BootDev: Socket
I-cache enabled
D-cache enabled (write-through)
L2 cache enabled. (L2CTL: 0xa0000000)
(write-through)
IPMC: v0.1.1
DOC: Turbo Mode
Net: eTSEC1, eTSEC2
ATCA-9305 (Mon 1.0)=>