Get Local FRU LED State
The Get Local FRU LED State command is used to read the local state of a FRU LED.
Table 7-39: Get Local FRU LED State Command
Type: Byte: Data Field:
Request Data 1:3 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
4 FRU Device ID
5LED ID
00h Blue LED (Hot Swap)
01h LED 1 (OOS)
02h LED 2
03h LED 3
04h-FEh OEM defined LEDs
FFh reserved (all LEDs under management control are
addressed)
Response Data 1 Completion Code
2:4 PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
5 Local Control LED Function
00h LED is off (default if Local Control not supported)
01h-FAh LED is blinking Off duration specified by this byte,
on duration specified by byte 5 (in tens of
milliseconds)
FBh-FEh reserved
FFh LED is on
6 Local Control On Duration
LED on-time is measured in tens of milliseconds
Lamp Test time in hundreds of milliseconds if byte 4=FBh, time
value must be less than 128. Other values when Byte 4=FBh are
reserved. Otherwise, this field is ignored and shall be set to 0h.
7 Color parameter specifies the color of the LED in the local state for
multi-color LEDs
8 If the off-first flag parameter is 0, the on part of the blink cycle of
the LED precedes the off part of the cycle. Otherwise, the off part