Fujitsu 480 Laptop User Manual


 
5-18 C122-E003-02EN
PSA
CHAPTER 5 Web-UI Operations
Table 5.10 Displayed and setting items in the [Storage Controller] window
Item Description
PCI Device Information
Unit SCSI storage controller identification name
Status Hardware status of the storage controller (but not including the
status of any subordinate device connected to it). This may differ
from the status displayed on the PCI device list.
OK: Operating normally
Error: Serious problem such as a hardware failure
Warning: Warning status (A problem may occur.)
Unknown: Unknown
Check the [Error] or [Warning] status check box to clear the status.
Additional note: Check the check box and then click the [Status
Clear] button to clear the status.
Device Name Device name that combines a vendor name and device name
In Windows: "SCSI Controllers" and other such names are
displayed for newly added devices after a hardware configuration
change. After thirty minutes or so, however, these names are
changed to device names recognized by the OS.
Device Class Device class ID (in hexadecimal)
Seg/Bus/Dev/Func The following numbers:
Segment number
Bus number
Device number
Function number
Vendor ID Vendor ID (in hexadecimal)
Device ID Device ID (in hexadecimal)
PCI Device Version PCI device version number (in hexadecimal)
Device Information Connected to Controller
Unit Storage controller identification name
Status Integrated status of the hardware status and predicted fault status
of individual devices connected to the storage controller:
OK: Operating normally
Error: Serious problem such as a hardware failure
Warning: Warning status (A problem may occur. This includes
S.M.A.R.T.)
Unknown: Unknown
Check the check box to clear the status.
Additional note: Check the check box and then click the [Status
Clear] button to clear the status.