Fujitsu J2X1-7611-03ENZ0 Computer Accessories User Manual


 
Key Description Default value
A number of days cannot be specified with this
method.
*1: Changes to this setting are enabled by executing the Change periodic log schedule settings command after changing the
settings file.
*2: If periodic_log_schedule_type is DAILY, the periodic_log_schedule_day value will be ignored.
An example of setting the operational settings file is shown below:
# delete setting of meteringlog database
# YYYY-MM-DD
# ex. 3 months ago 0000-03-00
retention_period=0000-03-00
# schedule of periodlog insert
periodic_log_use=yes
periodic_log_schedule_time=00:00
periodic_log_schedule_type=DAILY
periodic_log_schedule_day=
3. If an item other than retention_period has been changed, execute the Change periodic log schedule settings command.
Refer to "10.1 ctchg_chgschedule (Change Periodic Log Schedule Settings)" in the "Reference Guide (Command/XML) CE" for
information on the Change periodic log schedule settings command.
Note
Points to note when using the usage charge calculator
- Specify either the default value (3 months) or a period longer than the default value for retention_period.
- Do not change the values for the following keys from the default:
- periodic_log_use
- periodic_log_schedule_time
- periodic_log_schedule_type
- periodic_log_schedule_day
8.7.4 Usage Charge Calculator Settings
This section describes how to change the settings for the usage charge calculator function.
The procedure for changing the settings is as follows:
1. Open the following operating environment file:
[Windows Manager]
Installation_folder\RCXCTMG\Charging\conf\accounting.properties
[Linux Manager]
/etc/opt/FJSVctchg/conf/accounting.properties
2. Set the following items in the operating environment file:
- 38 -