GarrettCom MNS-6K Switch User Manual


 
MAGNUM 6K SWITCHES, MNS-6K USER GUIDE
Trunk Mismatch The other switch sent a BPDU which did not match the trunk
information associated with this port. This happens when the port is
connected to a different switch, or a different module in the Magnum
6K switch
The output of the LACP command in the network shown below
F
IGURE 107 – The network for the ‘show lacp’ command listed below
In the figure shown above, Switch 1 has ports 11 and 15 forming the first trunk, connecting to
Switch 3. Switch 1 also has ports 17 and 23 forming the second trunk on Switch 2. The ‘show
lacp’ command was executed on Switch 1.
Magnum 6K(lacp)## show lacp
Trunk Id : 1
Trunk Status : Trunk Active
Primary Port : 11
Trunk Partner : 00:20:06:25:11:40
Member Ports:
Port Priority Trunk
=====================
11 32768 Primary Port
15 32768 Member Port
Trunk Id : 2
Trunk Status : Trunk Active
Primary Port : 17
Ports belonging to thi
s
trunk
Unique ID of
trunk
M
AC address of
Switch 3
Switch 3
Switch 2
Switch 1
184