Syntax set-qi interval=<value> - The IGMP querier router periodically sends general host-query
messages. These messages are sent to ask for group membership information. This is sent to the all-
system multicast group address, 224.0.0.1. The default value is 125 seconds. The valid range can be
from 60 to 127 seconds.
Syntax set-qri interval=<value> - The query response interval is the maximum amount of time that
can elapse between when the querier router sends a host-query message and when it receives a response
from a host. The Default value is 10 seconds. The Range can be from 2 to 270 seconds. Restrictions
apply to the maximum value because of an internal calculation that is dependent on the value of the
Query Interval.
Magnum6K25# igmp
Magnum6K25(igmp)## set-port port=10-12 mode=forward
Port mode is set.
Magnum6K25(igmp)## set-port port=14-16 mode=block
Port mode is set.
Magnum6K25(igmp)## show-port
-----------------------------------
Port | Mode
-----------------------------------
09 Auto
10 Forwarding
11 Forwarding
12 Forwarding
13 Auto
14 Blocking
15 Blocking
16 Blocking
Magnum6K25(igmp)## show-router
RouterIp PortNo Timer
--------------------------------------
10.21.1.250 9 25
Magnum6K25(igmp)## set-leave enable
IGMP immediate leave status is enabled
Magnum6K25(igmp)## show igmp
IGMP State : Enabled
ImmediateLeave : Enabled
Querier : Enabled
205