GarrettCom MNS-6K Switch User Manual


 
MAGNUM 6K SWITCHES, MNS-6K USER GUIDE
Querier Interval : 125
Querier Response Interval : 10
Magnum6K25(igmp)## set-leave disable
IGMP immediate leave status is disabled
Magnum6K25(igmp)## show igmp
IGMP State : Enabled
ImmediateLeave : Disabled
Querier : Enabled
Querier Interval : 125
Querier Response Interval : 10
Magnum6K25(igmp)## set-querier enable
IGMP querier status is enabled
Magnum6K25(igmp)## show igmp
IGMP State : Enabled
ImmediateLeave : Disabled
Querier : Enabled
Querier Interval : 125
Querier Response Interval : 10
Magnum6K25(igmp)## set-querier disable
IGMP querier status is disabled
Magnum6K25(igmp)## show igmp
IGMP State : Enabled
ImmediateLeave : Disabled
Querier : Disabled
Querier Interval : 125
Querier Response Interval : 10
Magnum6K25(igmp)## set-qi interval=127
Query interval successfully set
Magnum6K25(igmp)## show igmp
IGMP State : Enabled
ImmediateLeave : Disabled
Querier : Disabled
Querier Interval 127
Querier Response Interval : 10
Magnum6K25(igmp)## set-qri interval=11
206