GarrettCom MNS-6K Switch User Manual


 
MAGNUM 6K SWITCHES, MNS-6K USER GUIDE
Command Description
clear <history|log [1..5 |informational
|activity |critical |fatal |debug]
|terminal |arp|portstats|addr]
clear command to clear various aspects of the
MNS-6K information – most notably “clear
addr” – clears the addresses learnt or “clear log”
to clear the logs (and the type of logs)
clear log
[fatal|alert|crit|error|warn|note|info|d
ebug]
clear logs or specific type of logs
climode <script|console|show>
set the interactive CLI mode on (console) or off
(script). To see the mode – use the show option
com2sec <add|delete> id=<id>
[secname=<name>] [source=<source>]
[community=<community>]
a part of the View based Access control model
(VACM) as defined in RFC 2275. This
specifies the mapping from a source/community
pair to a security name. On MNS-6K, up to 10
entries can be specified
command
<Enter>
options for a command
community [write=<write community>]
[read=<read community>] [trap=<trap
community>]
set the necessary community strings
configure access sets the access parameters e.g. disable telnet
session
cost port=<number|list|range>
value=<0-65535>
cost is specific to a port and the port(s) have to
be specified
configure port-security sets the port authorization based on MAC
addresses
configure vlan type=port enter the VLAN configuration commands
cost port=<number|list|range>
value=<0-65535>
cost is specific to a port and the port(s) have to
be specified
deftrap community=<string> defines the default community string to be used
when sending traps. When user does not specify
the trap community name when setting a trap
station using the “trap” command, the default
trap community name is used
280