GarrettCom MNS-6K Switch User Manual


 
MAGNUM 6K SWITCHES, MNS-6K USER GUIDE
Syntax show rmon <stats|hist|event|alarm> - list the specific RMON data as defined by the group
type
Chapter 19 – Miscellaneous
Commands
Syntax alarm – enter the alarm configuration mode
Syntax add event=<event-id|list|range|all> - enables alarm action in response to the specified event ID
Syntax period time=<1..10> - sets the duration of relay action for the momentary type signal. This may be
needed to adjust to the behavior of the circuit or relay. Default is 3 seconds. Time is in seconds
Syntax del event=<event-id|list|range|all> - disables alarm action in response to the specified event ID
Syntax alarm <enable|disable> - globally enables or disables the alarm action
Syntax show alarm - displays the current status of Alarm system
Syntax smtp – configure the SNMP alerts to be sent via email
Syntax show smtp <config|recipients> -
config
– displays the current SMTP global settings and
recipients
displays the currently configured recipients of email alerts
Syntax add id=<1-5> email=<email-addr> [traps=<all|none|S|R|E>]
[events=<all|none|I|A|C|F|D>] [ip=<ip-addr>] [port=<1-65535>]
id – [mandatory] the recipient ID - range from 1 to 5. MNS-6K allows a maximum of 5
recipients
email – [mandatory] email address of the recipient
traps – [optional] this is the trap filter. If value is “all”, all traps of any type will be sent to
this recipient. If value is none, no traps are sent to this recipient. Value can also be
a combination of ‘S’ (SNMP), ‘R’ (RMON) and ‘E’ (ENTERPRISE). For example,
trap=SR means that SNMP and RMON traps will be sent via email to the recipient.
If this option is not defined, the recipient will have a default value of “all”
events – [optional] this is the event filter. Value can be “all” - all event severity types will
be sent to recipient, “none” - no event will be sent to recipient or a combination of
‘I’ (informational), ‘A’ (activity), ‘C’ (critical), ‘F’ (fatal) and ‘D’ (debug). With
275