GarrettCom MNS-6K Switch User Manual


 
MAGNUM 6K SWITCHES, MNS-6K USER GUIDE
Warning – changing these parameters through the serial port will cause loss
of connectivity – the parameters of the terminals software (e.g. Hyper
Terminal etc.) will also have to be changed to match the new settings.
To see the current settings of the serial port, use the ‘show serial’ command.
Magnum6K25# show serial
Baud Rate : 38400
Data : 8
Parity : No Parity
Stop : 1
Flow Control : None
FIGURE 25 - Querying the serial port settings
System parameters
The system parameters can be queried and changed. To query the system parameters, two
commands are used frequently. They are ‘show sysconfig’ and ‘show setup’. Both the
commands are shown below.
Magnum6K25# show setup
Version : Magnum 6K25 build 3.7.1 Sep 27 2007 16:41:37
MAC Address : 00:20:08:03:05:09
IP Address : 192.168.5.5
Subnet Mask : 255.255.255.0
Gateway Address : 192.168.5.1
CLI Mode : Manager
System Name : Magnum 6K25
System Description : 25 Port Modular Ethernet Switch
System Contact : support@garrettcom.com
System Location : Fremont, CA
System ObjectId : 1.3.6.1.4.1.553.12.6
System Seriial No. : 43576812
Original Factory Config Code : 6K25-8TP
Magnum6K25#
FIGURE 26 - System parameters using the show setup command. Most parameters here cannot be
changed
41