62.00.00 No system To continue, turn off then on
Description
Internal system failure
Recommended action
Turn the product off, and then on.
If the error persists, reload the firmware. If the error still persists, perform a firmware upgrade.
If the firmware upgrade does not resolve the problem, replace the hard disk.
70.00.00 Error To continue, turn off then on
Description
DC controller failure
Recommended action
Turn the product off, and then on.
If the error persists, replace the DC controller.
80.0X.YY Embedded JetDirect error
Description
Embedded HP JetDirect print server critical error
◦
80.01.80 (event code)
No heartbeat
◦
80.01.81 (event code)
Reclaim timeout
◦
80.01.82 (event code)
Invalid data length
◦
80.01.8B (event code)
Invalid max outstanding packet header field
◦
80.01.8C (event code)
Invalid channel mapping response
◦
80.03.01 (event code)
No PGP buffers
◦
80.03.02 (event code)
452 Chapter 3 Solve problems ENWW