Table 3-51 Causes and solutions for fuser delivery stationary jams
Cause Solution
The fuser roller or pressure roller is worn or
deformed.
Replace the fuser. See
Fuser on page 93.
The fuser-delivery roller is deformed.
The gear of the fuser-delivery roller is
damaged.
Poor contact of the fuser-output sensor
connector.
Reconnect the connector J131 on the DC controller PCA.
The fuser-output sensor (PS6) is defective. Run the manual sensor test to verify that the fuser-output sensor is functioning
properly. See
Fuser output sensor (PS6) on page 297. If it is not, replace the
fuser. See
Fuser on page 93.
Jams in the duplex area (duplex models only)
Table 3-52 Causes and solutions for duplexing reverse jams
Cause Solution
The duplex reverse roller is worn or deformed. Replace the fuser. See
Fuser on page 93.
The duplex feed roller is worn or deformed. Replace the right door. See
Right-door assembly on page 126.
Poor contact of the duplex reverse-motor (M7)
connector
Reconnect the connectors (J520) on the duplex reverse motor, intermediate
connectors (J552L and J552D), connector (J1006) on the driver PCA, and
connectors (J93; J92; J91) on the DC controller PCA.
The duplex reverse motor is defective. Replace the duplex drive assembly. See
Duplex drive assembly (duplex
models) on page 187.
Table 3-53 Causes and solutions for duplex repick jams
Cause Solution
The duplex re-pickup sensor lever is set
incorrectly or damaged.
Check the sensor lever to make sure it is set correctly. If it is damaged, replace
the right door assembly. See
Right-door assembly on page 126.
The spring of the duplex re-pickup sensor
lever is unhooked.
Check the spring and place it in correct position.
Poor contact of the duplex reverse solenoid
(SL3) connector
Reconnect the intermediate connectors (J522L and J522D), connector (J1005)
on the driver PCA, and connectors (J93; J92; J91) on the DC controller PCA.
The duplex reverse solenoid is defective. Replace the duplex-drive assembly. See
Duplex drive assembly (duplex
models) on page 187.
The duplex flapper is damaged or
malfunctioning.
Replace the delivery assembly. See
Duplex drive assembly (duplex models)
on page 187.
The duplex reverse solenoid is defective. Replace the duplex-drive assembly. See
Duplex drive assembly (duplex
models) on page 187.
ENWW
Clear jams
509