7 I/F time-out occurs between the printer and the operator panel (ERROR 80) .
Is the connecting cord of the operator panel connected to the PANEL connector of the
Main board properly? (See Chapter 7.1.)
No Connect the connecting cord of the operating panel to the PANEL connector of
the Main board properly.
Yes Is the connecting cord defective?
Yes Replace the connecting cord.
No Replace the operator panel assembly.
Is the printer recovered?
No Replace the Main board.
YES END
5 I/F time-out between printer and optional tray (ERROR 81) .
Is an optional tray (2nd / 3rd tray or envelope feeder) used?
Yes Is the connection between the Main board and the optional tray connected
properly. (See Chapter 7.1.)
No Connect the cable properly.
Yes Replace the Main board.
Is the printer recovered?
No Isolate the trouble by following the 2nd/ 3rd tray or multi feeder
maintenance manual. (See Appendix C or D.)
YES END
No Replace the Main board.
6 I/F time-out between printer and Duplex Unit (ERROR 83)
Is an Duplex Unit used?
Yes Is the connection between the Main board and the Duplex Unit connected
properly. (See Chapter 7.1.)
No Connect the cable properly.
Yes Replace the Main board.
Is the printer recovered?
No Isolate the trouble by following the Duplex Unit maintenance manual.
(See appendix C.)
YES END
No Replace the Main board.