40930701TH DRAFT Vesion 86 /
3.3.27 Power supply unit
(1) Turn the AC power switch off. Unplug the AC power cord from the outlet.
(2) Remove the frame main [See 3.3.12(7)]
(3) Unscrew 2 screws 1 and remove the BRACKET-AC 2.
(4) Unscrew 10 screws 3 and remove the connector 6 remove the Power supply unit [AC-
DC(120/230V)] 4 and Power supply unit (High voltage) 5.
2
4
5
1
3
6
3
3
3