Panasonic KX-T61610 Switch User Manual


 
:.-.......-.-----
until the desired CO number appears
until the desiredflash timing appears
:.
[34] [NEXT] [NEI(T] [SELECT] [MEMYRY] [END]
or
[34] [NEXT] [A] [SELECT] [MEMORY] [END]
--/-
I~~~~~~~~~-._.._.~-~~-~-~---~~ A=[*]: to assign the same on all 6 CO’s
Description
The timing of the hookswitch flash signal must
be within the requirements from your Central
Office.
There are three choices available 0.3, 0.6 or 0.9
second.
Programming
1. Dial (34).
“FLASH TIME SET” will be displayed.
2. Press the NEXT button.
“ENTER CO NO” will be displayed.
3. Press the NEXT button.
“CO 1: 600 MS” will be displayed and
“600 MS” will blink.
4. Repeat pressing the SELECT button until the
desired value is displayed.
5. Press the MEMORY button.
The LCD will stop blinking.
6.
Repeat steps 3 to 5, to set the hookswitch
timing of the other CO’s.
7. To return to the initial program mode, press
the END button.
Conditions
0 When you start the programming from step I,
you may dial the desired CO number instead
of the NEXT button at step 3.
OThe PREV button allows you to go to the
previous CO for displaying the hookswitch
flash timing.
Example:
l
O.3 set on all 6 CO= .
[34] [NEXT] [++I [SELECT] [SELECT] [MEMORY]
[END1
Programming Table
See page 6-20.
3-49