I....-.until the desired CO number appears
[36][NEXT][NEXT][SELECTj[MEMPRYJ[END]
or
f I
[36] [NEXT] [A] [SELECT] [MEMORY] [END]
--7-
Description
To detect that an outside party has hung up and
then terminate the outside (after a conversation,
conference etc.) a CPC signal is needed.
CPC signal detection can be removed or added
at customer’s request.
Programming
1.
Dial (36).
“CPC DETECTION” will be displayed.
2. Press the NEXT button.
“ENTER CO NO” will be displayed.
3. Press the NEXT button.
“CO I: ENABLE” will be displayed and
“ENABLE” will blink.
4. Press the SELECT button, to alternate be-
tween ENABLE and DISABLE to select the
desired mode.
6. Repeat steps 3 to 5, to program the assign-
ment of the other CO’s.
7. To return to the initial program mode, press
the END button.
Conditions
l
When you start the programming from step 1,
you may dial the desired CO number instead
of the NEXT button at step 3.
~The PREV button allows you to go to the
previous CO for displaying the calling party
control signal selection.
Programming Table
See page 6-20.
5. Press the MEMORY button.
The LCD will stop blinking.
3-51