Pelco C1566M-C Switch User Manual


 
116 C1572M (9/05)
Camera Control Commands
Focus Near Na Causes the currently selected camera to adjust the focus range
nearer to the camera.
Stop Focus Near ~Na Stops the focusing of the currently selected camera.
Focus Far Fa Causes the currently selected camera to adjust the focus range
farther from the camera.
Stop Focus Far ~Fa Stops the focusing of the currently selected camera.
Iris Open Oa Opens the iris of the currently selected camera and brightens
the image.
Stop Iris Open ~Oa Stops opening the iris of the currently selected camera.
Iris Close Ca Closes the iris of the currently selected camera and darkens the
image.
Stop Iris Close ~Ca Stops closing the iris of the currently selected camera.
Zoom Telephoto Ta Narrows the field of view of the currently selected camera and
makes objects appear larger (zooms in).
Stop Zoom Telephoto ~Ta Stops the currently selected camera from zooming in.
Zoom Wide Wa Widens the field of view of the currently selected camera and
makes objects appear smaller (zooms out).
Stop Zoom Wide ~Wa Stops the currently selected camera from zooming out.
Advanced Commands
Start Record Pattern [1-99]/a On receivers that do patterns, the Start Record Pattern
command allows recording of a user-defined pattern. A value
ranging from 1 to 99 equals the pattern number. (Consult the
receiver manual for specific information regarding
implementation.)
Stop Record Pattern [1-99]/a Stops the recording of a pattern.
NOTE: The Start Record Pattern command functions as a
toggle. Issuing the [1-99]/a command starts the recording of a
pattern. Issuing the command a second time stops recording
the pattern.
NOTE: In some instances, entering the pattern number as part
of the command is optional. For example, Spectra II
and the
ES3000 Series Esprit
units are capable of recording one full
pattern or two half-patterns. Issuing the /a command starts
full-pattern recording. Issuing the /a command again stops full-
pattern recording. Half-pattern programming follows the same
sequence, except that the pattern number must be included in
the command to start and stop pattern recording.
Start Pattern [1-99]pa Starts the pattern. A value ranging from 1 to 99 equals the
pattern number. (Consult the receiver manual for specific infor-
mation regarding implementation.)
Stop Pattern [1-99]na Stops the pattern.
Table P. ASCII Command Descriptions (Continued)
Action Command* Command Description