Pelco C1566M-C Switch User Manual


 
22 C1572M (9/05)
MOUNTING THE CM9760-MXB
To mount a CM9760-MXB into a rack, install the CM9760-MXB into the desired location and secure the unit using the supplied mounting
hardware (refer to Figure 6).
Figure 6. Mounting the CM9760-MXB
If you are mounting multiple matrix bays, note the following:
If you are installing a new system, be sure to mount the matrix bays in a horizontal (sideframe) or vertical (downframe) manner according to
the bay location label provided on the rear of each matrix bay (refer to the Selecting a Location for the CM9760-MXB section for additional
information.)
After mounting matrix bays in a downframe configuration, connect each supplied coaxial ribbon cable, referred to as a downframe cable, to
downframe connectors on rear panel cards as appropriate. The downframe cables are required to connect the video inputs from one matrix
bay to another. Figure 7 illustrates sample downframe cable connections between a CM9760-RPC card and a CM9760-DFC card and
between a CM9760-RPC card and a CM9760-DFL card in a configuration containing one downframed bay. For additional information, refer
to Downframing in the CM9760-MXB Matrix Bay section and to Appendix B.
DANGER: Always install equipment starting from the bottom of the rack. Installing equipment starting from the top of the rack can cause
the rack to topple.