Pelco C1566M-C Switch User Manual


 
C1572M (9/05) 43
INSTALLING OR REPLACING A CM9760-RPM REAR PANEL OUTPUT CARD
Only one CM9760-RPM card can be installed into the rear of the matrix bay. The card must always be installed into the leftmost slot. From the
rear of the bay, the leftmost slot provides the connection point for the CM9760-VMC video output card, which is always installed into slot 17 in
the front of the bay. If necessary, a CM9760-RPM card can be replaced. To install or replace a CM9760-RPM card, refer to the sections that
follow.
Installing a CM9760-RPM Card
NOTE: A CM9760-RPM card must be installed before the associated CM9760-VMC video input card is installed.
To install a CM9760-RPM card, do the following:
1. Ensure that termination jumpers JP1-JP16 are set in the unterminated position (positions 2 and 3) (refer to Figure 26).
Figure 26. Termination Jumpers on CM9760-RPM Card
2. Locate the desired slot position at the rear of the bay.
3. Remove the blank cover plate by loosening the screw at the top and bottom of the plate.
4. Slide the new card into the card guides of the leftmost slot (refer to Figure 27).
WARNINGS:
Rear panel card installation should be performed by qualified personnel only.
Electrostatic discharge (ESD) precautions must be observed when installing a rear panel card. Always wear a grounding strap
connected to an approved grounding source when working on or near exposed electronic equipment.
JP1-JP16
TERMINATEDUNTERMINATED