Installation and Operation Manual Chapter 6 Troubleshooting and Diagnostics
ASMi-52 Ver. 2.5 Testing ASMi-52 6-23
To activate the remote loopback at the SHDSL repeater:
1. From the Diagnostics menu, select Repeater Test (Main menu > Diagnostics
> Repeater Test).
The Repeater Test menu appears (see Figure 6-26).
2. From the Repeater Test menu, select Repeater Number and choose a
repeater when you intend to activate the RLB Network.
3. From the Repeater Test menu, select RLB Network.
The RLB Network value in parenthesis changes to ON. Also, an additional
parameter, Loop Timeout, is displayed.
4. Once you selected the loopback timeout, select Save to activate the RLB
Network.
The RLB at the repeater is initiated.
Data
Local ASMi-52 Repeater 1 Repeater 2
Data
Clock
Clock
Line
Interface
Customer
Interface
Customer
Interface
Network
Interface
Network
Interface
Transmit
Receive
Local
DTE
Glue
Logic
Figure 6-25. Remote Digital Loopback at the SHDSL Repeater
ASMi-52
Repeater Test
1. RLB Network (ON)
2. Loop Timeout(min)[0 - 4095] ... (5)
3. Repeater number > (1)
4. Save
>
ESC-prev. menu; !–main menu ; &–exit
Figure 6-26. Repeater Test Menu
Deactivating the Loopbacks
To deactivate a running loopback:
• From the Local or Remote Test menu, type the number corresponding to the
loopback in progress to change its value from ON to OFF and choose Save.
The TST indicator turns off.