Chapter 1 Introduction Installation and Operation Manual
1-8 Overview ASMi-52 Ver. 2.5
Table 1-4. Possible Multiplexer Applications (Cont.)
CO/CPE E1 Serial DTE LAN
E1+Serial DTE E1+LAN
Serial
DTE+LAN
E1↔E1 E1↔Serial DTE E1↔LAN
E1↔E1+Serial
DTE
E1↔E1 E1↔Serial DTE
E1+LAN↔E1 E1↔E1
E1↔Serial DTE E1↔E1+LAN
E1↔Serial
DTE+LAN
E1+LAN↔E1 E1+LAN↔E1
E1+LAN
E1+LAN↔
E1+LAN
Serial DTE↔E1
Serial DTE↔
Serial DTE
Serial
DTE↔LAN
Serial DTE↔E1
Serial DTE
↔Serial DTE
Serial DTE+
LAN↔E1
Serial DTE↔E1
Serial DTE↔
Serial DTE
Serial DTE+
LAN↔E1
Serial DTE+
LAN↔E1
Serial
DTE+LAN
Serial DTE
+LAN↔Serial
DTE +LAN
DXC
DXC↔E1+
Serial DTE
DXC↔E1
+LAN
DXC↔Serial
DTE+LAN
LRS-24
LRS-24↔
E1+Serial DTE
LRS-24↔
E1+LAN
LRS-24↔Serial
DTE+LAN
Serial DTE = V.35, X.21, RS-530, IR-IP
The following are multiplexer conditions when working with the ASMi-52 unit:
• E1+Serial DTE can work as an ‘E1 port only’.
• E1+LAN can work as an ‘E1 port only’.
• LAN+Serial DTE can work as a ‘Serial DTE port only’.
• E1+Ethernet and Serial DTE+Ethernet can be configured as a single port only
(‘E1 only’ or ‘Serial DTE only’) while the Ethernet port operates as a
management port only.
ASMi-52 E1 or Serial DTE units with a LAN management port previously released
with software versions earlier than version 2.5 cannot operate as a multiplexer unit
(E1+LAN, Serial DTE+LAN) with version 2.5 due to hardware differences.
Timing
ASMi-52 supports three clock modes:
• Internal, derived from its internal oscillator (CO mode)
• External, supplied by the attached DTE
Note
Note