RAD Data comm ASMi-52 Network Router User Manual


 
Installation and Operation Manual Chapter 4 Configuration
ASMi-52 Ver. 2.5 Configuring the Physical Ports 4-27
Configuring the DTE Interface Data Rate
ASMi-52 supports multiple data rates between the range of 64 kbps and
4608 kbps, depending on the clock mode and line/DTE interface of the local and
remote units (see Table 1-2 and Table 1-3).
To select the data rate:
1. From the DTE Local Port menu, select Data Rate.
The Data Rate menu appears (see Figure 4-31). The ASMi-52 screen in
Figure 4-31 is with a 2-wire, internal clock configuration.
2. Select the data rate by typing the number corresponding to the required value,
and press <Enter>.
The DTE Local Port menu appears.
3. Select Save to save the changes.
ASMi-52
Data Rate (384 Kbps)
1. 64 Kbps 13. 832 Kbps 25. 1600 Kbps
2. 128 Kbps 14. 896 Kbps 26. 1664 Kbps
3. 192 Kbps 15. 960 Kbps 27. 1728 Kbps
4. 256 Kbps 16. 1024 Kbps 28. 1792 Kbps
5. 320 Kbps 17. 1088 Kbps 29. 1856 Kbps
6. 384 Kbps 18. 1152 Kbps 30. 1920 Kbps
7. 448 Kbps 19. 1216 Kbps 31. 1984 Kbps
8. 512 Kbps 20. 1280 Kbps 32. 2048 Kbps
9. 576 Kbps 21. 1344 Kbps 33. 2304 Kbps
10. 640 Kbps 22. 1408 Kbps ………….
11. 704 Kbps 23. 1472 Kbps 72. 4608 Kbps
12. 768 Kbps 24. 1536 Kbps
>
ESC-prev. menu; !-main menu; &-exit; @-scroll
Figure 4-31. Typical Data Rate Menu
Configuring the Data Rate in a Multiplexer Unit
The maximum multiplexer rate is 2048 kbps (general rate). The sum of the data
rate of two interfaces should not exceed 2048 kbps.
ASMi-52 is a multiplexer modem with two interfaces that has the following
maximum rate for Serial DTE interface:
If DTE Serial + E1 interface, then the DTE Serial maximum rate = 2048 kbps
– used TSs (timeslots) x 64 kbps.
If DTE Serial + LAN interface, then the DTE Serial maximum rate =
2048 kbps – LAN rate.