Appendix H- Mounting the SonicWALL PRO 200 and PRO 300
The SonicWALL PRO 200 and SonicWALL PRO 300 are designed to be mounted in a standard 19-
inch rack mount cabinet. The following conditions are required for proper installation:
Use the mounting hardware recommended by the rack manufacturer and ensure that the rack
is adequate for the application.
Four mounting screws, compatible with the rack design, must be used and hand tightened to
ensure secure installation. Choose a mounting location where all four mounting holes line up
with those of the mounting bars of the 19-inch rack mount cabinet.
Mount in a location away from direct sunlight and sources of heat. A maximum ambient temper-
ature of 104º F (40º C) is recommended.
Route cables away from power lines, fluorescent lighting fixtures, and sources of noise such as
radios, transmitters, and broadband amplifiers
Ensure that no water or excessive moisture can enter the unit.
Allow unrestricted airflow around the unit and through the vents on the side of the unit. A mini-
mum of 1 inch (25.44mm) clearance is recommended.