96 Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide • October 2001
Note – Stop all device activity to each Fabric device on the selected port and
unmount any filesystems on each Fabric device. If the device is under any volume
manager’s control, see the documentation for your volume manager for maintaining
the Fabric device.
Note – This operation repeats the configuration operation of an individual device
for all the devices on c0, and may be time consuming if the number of devices on c0
is large.
4. Verify that all devices on c0 are configured.
# cfgadm -c configure c0
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected configured unknown
c0::50020f23000063a9 disk connected configured unknown
c0::50020f2300005f24 disk connected configured unknown
c0::50020f2300006107 disk connected configured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c1::220203708b8d45f2 disk connected configured unknown
c1::220203708b9b20b2 disk connected configured unknown