Sun Microsystems 816-0830-12 Switch User Manual


 
102 Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide October 2001
3. Configure Fabric devices and create Sun StorEdge Traffic Manager devices.
4. Verify that the selected devices are configured.
Notice that the Occupant column of both c0 and c0::50020f2300006077
specifies configured, indicating that the c0 port has configured occupants and that
the c0::50020f2300006077 device is configured. The same change has been made on
c2 and c2::50020f2300006107.
After the cfgadm -c configure command completes without an error, the Sun
StorEdge Traffic Manager devices are created on the Solaris host.
CODE EXAMPLE 8-3
shows output for a Sun StorEdge T3 enterprise array. Notice that two Sun StorEdge
Traffic Manager devices,
/dev/rdsk/c6t60020F20000061073AC8B52D000B74A3d0s2
and
/dev/rdsk/c6t60020F20000061073AC8B4C50004ED3Ad0s2,
are created for the device represented by c0::50020f2300006077 and
c2::50020f2300006107. This indicates that the physical device represented by
c0::50020f2300006077 and c2::50020f2300006107 has two LUNs configured.
# cfgadm -c configure c0::50020f2300006077 c2::50020f2300006107
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected configured unknown
c0::50020f23000063a9 disk connected unconfigured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c1::220203708b8d45f2 disk connected configured unknown
c1::220203708b9b20b2 disk connected configured unknown
c2 fc-fabric connected configured unknown
c2::50020f2300005f24 disk connected unconfigured unknown
c2::50020f2300006107 disk connected configured unknown
CODE EXAMPLE 8-3
# luxadm display 50020f2300006077
DEVICE PROPERTIES for disk: 50020f2300006077
Status(Port A): O.K.
Status(Port B): O.K.