32 Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide October 2001
Note You must enable Sun StorEdge Traffic Manager software or use Veritas
VxDMP 3.2 for failover across multiple hosts to function. The mp_support on the
Sun StorEdge T3 should be set to mpxio.
Setting the Loop ID
Setting the loop ID of the Sun StorEdge A3500 FC array is different from the
procedure for the Sun StorEdge A5200 array and for the Sun StorEdge T3 array.
To Set the Loop ID of a Sun StorEdge A3500 FC
Controller
This section explains how to set the loop ID of a Sun StorEdge A3500 FC controller
that is connected to a switch.
Tools and equipment needed:
Needle-nose pliers
Jumpers (supplied with the Sun StorEdge A3500/A3500FC unit)
Antistatic wrist strap
Every device attached to a SCSI or FC-AL bus must have a unique controller module
ID number in order to communicate. The factory default ID settings for controller A
and B are ID 5 and ID 4, respectively.
Caution Do not configure more than four controller modules on the same loop.
1. Attach the antistatic wrist strap to your wrist and to the metal casing of the switch.
2. Locate the 16 pins on the rear of the FC-AL controller module (
FIGURE 2-15).
The eight pins on the right determine the host ID for controller 1 (A); the pins on the
left determine the ID for controller 2 (B).
3. Install the jumpers on the pins as shown in
FIGURE 2-15.
If necessary, use the needlenose pliers to remove the jumpers.