Sun Microsystems 816-0830-12 Switch User Manual


 
110 Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide October 2001
1. Become superuser.
2. Identify a Fabric-connected host port to be configured.
Devices represented by attachment point IDs c0::50020f2300006077 and
c2::50020f2300006107 are two paths to the same physical device, with
c0::50020f2300006077 already being configured. The luxadm display in
CODE EXAMPLE 8-7 shows the Solaris device associated with this path. One path is
configured.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected configured unknown
c0::50020f23000063a9 disk connected configured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c1::220203708b8d45f2 disk connected configured unknown
c1::220203708b9b20b2 disk connected configured unknown
c2 fc-fabric connected unconfigured unknown
c2::50020f2300005f24 disk connected unconfigured unknown
c2::50020f2300006107 disk connected unconfigured unknown
CODE EXAMPLE 8-7
# luxadm display 50020f2300006077
DEVICE PROPERTIES for disk: 50020f2300006077
Status(Port A): O.K.
Vendor: SUN
Product ID: T300
WWN(Node): 50020f2000006077
WWN(Port A): 50020f2300006077
Revision: 0117
Serial Num: Unsupported
Unformatted capacity: 558448.000 MBytes
Write Cache: Enabled
Read Cache: Enabled
Minimum prefetch: 0x0
Maximum prefetch: 0x0
Device Type: Disk device
Path(s):
/dev/rdsk/c6t60020F20000061073AC8B52D000B74A3d0s2
/devices/scsi_vhci/ssd@g60020f20000061073ac8b52d000b74a3:c,raw
Controller /devices/pci@1f,2000/pci@1/SUNW,qlc@5/fp@0,0