112 Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide October 2001
4. Verify that all devices on c2 are configured.
Notice that the Occupant column of both c2 and all of the devices under c2 as
configured.
Compare the luxadm output in
CODE EXAMPLE 8-8 with that in CODE EXAMPLE 8-7 on
page 110. Notice the addition of a new path to the Sun StorEdge Traffic Manager
device.
# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c0 fc-fabric connected configured unknown
c0::50020f2300006077 disk connected configured unknown
c0::50020f23000063a9 disk connected configured unknown
c1 fc-private connected configured unknown
c1::220203708b69c32b disk connected configured unknown
c1::220203708ba7d832 disk connected configured unknown
c1::220203708b8d45f2 disk connected configured unknown
c1::220203708b9b20b2 disk connected configured unknown
c2 fc-fabric connected configured unknown
c2::50020f2300005f24 disk connected configured unknown
c2::50020f2300006107 disk connected configured unknown
CODE EXAMPLE 8-8
# luxadm display 50020f2300006077
DEVICE PROPERTIES for disk: 50020f2300006077
Status(Port A): O.K.
Status(Port B): O.K.
Vendor: SUN
Product ID: T300
WWN(Node): 50020f2000006077
WWN(Port A): 50020f2300006077
WWN(Port B): 50020f2300006107
Revision: 0117
Serial Num: Unsupported
Unformatted capacity: 558448.000 MBytes
Write Cache: Enabled
Read Cache: Enabled
Minimum prefetch: 0x0
Maximum prefetch: 0x0
Device Type: Disk device
Path(s):
/dev/rdsk/c6t60020F20000061073AC8B52D000B74A3d0s2
/devices/scsi_vhci/ssd@g60020f20000061073ac8b52d000b74a3:c,raw