Sun Microsystems 816-0830-12 Switch User Manual


 
128 Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide October 2001
Managing IP Networks in a SAN
This section contains the following topics:
“Installation” on page 128
“Configuration” on page 131
“Invocation” on page 131
“Usage” on page 132
Installation
The FCIP depends on the instance of fp. If multiple HBAs are present, plumb
manually after identifying the fp instance on which IP should be plumbed. The
following two procedures determine fp instances.
“To Determine All FP Instances to Which IP Can Be Plumbed” on page 128
“To Determine an FP Instance for a Known HBA Port Physical Device Path” on
page 129
To Determine All FP Instances to Which IP Can
Be Plumbed
1. Become root.
2. Determine fp instances.
There are four instances (0-3) of fp present in the system.
# prtconf -v | grep fp
fp (driver not attached)
fp, instance #0
fp (driver not attached)
fp, instance #1
fp (driver not attached)
fp, instance #2
fp (driver not attached)
fp, instance #3