Sun Microsystems 816-0830-12 Switch User Manual


 
104 Sun StorEdge Network FC Switch-8 and Switch-16 Installation and Configuration Guide October 2001
Note The luxadm (1M) output on 50020f2300006107 will show the same
information as the previous display.
To Unconfigure a Fabric Device Associated With Sun
StorEdge Traffic Manager Devices
This example shows a Fabric-connected host ports c0 and c2 to illustrate how to
unconfigure Fabric devices associated with Sun StorEdge Traffic Manager devices.
Note Whether Sun StorEdge Traffic Manager is enabled or not, the unconfigure
operation for Fabric devices is identical but the result of the operation is different.
When the Sun Storage Traffic Manager software is enabled, the Solaris host creates
device node and path information that includes Sun StorEdge Traffic Manager
information.
1. Become superuser.
2. Identify the port WWN of the Fabric device to be unconfigured.
You can obtain port WWNs of Sun StorEdge T3 arrays by using the Sun StorEdge
Component Manager software.
/devices/scsi_vhci/ssd@g60020f20000061073ac8b4c50004ed3a:c,raw
Controller /devices/pci@1f,2000/pci@1/SUNW,qlc@4/fp@0,0
Device Address 50020f2300006107,0
Class primary
State ONLINE
Controller /devices/pci@1f,2000/pci@1/SUNW,qlc@5/fp@0,0
Device Address 50020f2300006077,0
Class secondary
State STANDBY
CODE EXAMPLE 8-3 (Continued)